Re: WebCatalog complains that the service is not running.

This WebDNA talk-list message is from

1998


It keeps the original formatting.
numero = 18909
interpreted = N
texte = > I am running WebCatalog 2 and IIS 4. After reinstalling IIS, the >WebCatalog suffix settings were lost from IIS. In an attempt to restore >those suffix settings I reinstalled WebCatalog. Reinstalling WebCatalog did >not restore the suffix settings as the manual seemed to imply.IIS4 threw everyone a loop because it changes the way suffix mappings are set (no longer from the Registry). In general you can see some interesting log information in the Event Viewer log to see if WebCat service is complaining about something.I recommend you shut down the WebCat service and run the DBServer.exe standalone. That way when you see its little window, you know for sure it is running. If it comes up and goes down instantly, then you need to restart NT because it has gotten confused about which services are running.Once you know DBServer.exe is running, then if you ever see DBServer not running messages, it's time to start looking at what versions of $WebCat.dll vs. DBServer.exe you have installed, to make sure they are in synch.Technical Support | ==== eCommerce and Beyond ==== Pacific Coast Software | WebCatalog, WebMerchant, 11770 Bernardo Plaza Court | SiteEdit Pro, PhotoMaster, San Diego, CA 92128 | Typhoon 619/675-1106 Fax: 619/675-0372 | http://www.smithmicro.com/ Associated Messages, from the most recent to the oldest:

    
  1. Re: WebCatalog complains that the service is not running. (Jeff Weston 1998)
  2. Re: WebCatalog complains that the service is not running. (PCS Technical Support 1998)
  3. WebCatalog complains that the service is not running. (Jeff Weston 1998)
> I am running WebCatalog 2 and IIS 4. After reinstalling IIS, the >WebCatalog suffix settings were lost from IIS. In an attempt to restore >those suffix settings I reinstalled WebCatalog. Reinstalling WebCatalog did >not restore the suffix settings as the manual seemed to imply.IIS4 threw everyone a loop because it changes the way suffix mappings are set (no longer from the Registry). In general you can see some interesting log information in the Event Viewer log to see if WebCat service is complaining about something.I recommend you shut down the WebCat service and run the DBServer.exe standalone. That way when you see its little window, you know for sure it is running. If it comes up and goes down instantly, then you need to restart NT because it has gotten confused about which services are running.Once you know DBServer.exe is running, then if you ever see DBServer not running messages, it's time to start looking at what versions of $WebCat.dll vs. DBServer.exe you have installed, to make sure they are in synch.Technical Support | ==== eCommerce and Beyond ==== Pacific Coast Software | WebCatalog, WebMerchant, 11770 Bernardo Plaza Court | SiteEdit Pro, PhotoMaster, San Diego, CA 92128 | Typhoon 619/675-1106 Fax: 619/675-0372 | http://www.smithmicro.com/ PCS Technical Support

DOWNLOAD WEBDNA NOW!

Top Articles:

Talk List

The WebDNA community talk-list is the best place to get some help: several hundred extremely proficient programmers with an excellent knowledge of WebDNA and an excellent spirit will deliver all the tips and tricks you can imagine...

Related Readings:

Encrypt/Decrypt (2007) Invisible file issue now a real 'bug' (1999) no global [username] or [password] displayed ... (1997) possible, WebCat2.0 and checkboxes-restated (1997) Hiding HTML and breaking the page (1997) Help! WebCat2 bug (1997) emailer error -108 (1997) Mystery authentication (1997) Summing fields (1997) Ok here is a question? (1997) different show next (1997) [WebDNA] ideas as to why [shell] call to imagemagick is failing intermittently? (2011) (1997) expired beta (1997) Re[2]: searches with dash, period etc. (back form politenes (2000) WebCat2.0 [format thousands .0f] no go (1997) F3 crashing server (1997) [WebDNA] reverse rank=off (2008) PCS Customer submissions ? (1997) WebObjects (1998)